Real Manufacturer Contec Cms6000 FDA Ce Medical Examiner Equipment Patient Monitor Vital Sign

Model NO.: CMS6000
Parameters: ECG, SpO2, NIBP
Model: Cms 6000
Standard Parameters: ECG,SpO2,NIBP,Pr,Temp,Resp
Screen: 8′′ TFT Color LCD
Warranty: 18-Month for Main Unit
Multi-Language Interface: Yes
Trademark: CONTEC
Transport Package: Carton
Specification: CE
Origin: Hebei, China
HS Code: 9018193010
Model NO.: CMS6000
Parameters: ECG, SpO2, NIBP
Model: Cms 6000
Standard Parameters: ECG,SpO2,NIBP,Pr,Temp,Resp
Screen: 8′′ TFT Color LCD
Warranty: 18-Month for Main Unit
Multi-Language Interface: Yes
Trademark: CONTEC
Transport Package: Carton
Specification: CE
Origin: Hebei, China
HS Code: 9018193010
Real manufacturer CONTEC CMS6000 FDA CE medical examiner equipment patient monitor vital sign
Model:CMS6000    Brand:CONTEC

Real Manufacturer Contec Cms6000 FDA Ce Medical Examiner Equipment Patient Monitor Vital Sign

CMS6000
 CE approved Portable Multiparameter Patient Monitor with 8'' TFT color LCD:
1All-round monitor for adult, pediatric and neonate.
2.Multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakhstan, Polish, Czech).
3.
Connect to Central Monitoring System by 3G, WiFi or wired mode.
4.Achieve data storage and software updating by USB interface
 
Main Features

1.Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
2.With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.
3.Waveform, parameter color and location can be set optionally.
4.Operation mode: keys and buttons.
5.Display up to 8-channel waveform on one screen.
6.Display 7-lead ECG waveform on one screen, and with ECG step function.
7.Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
8.HRV analysis function.
9.NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
10.Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
11.Drug concentration calculation and titration table functions.
12.Print trend table data with one-key.
13.AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
14.Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).

Functions
Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
1)ECG Heart rate(HR)
ECG waveform 
Arrhythmia and ST-segment analysis
2)RESP Respiration rate(RR)
Respiration waveform
3)SpO2 Oxygen saturation(SpO2)
Plethysmogram(PLETH) waveform
Pulse rate(PR)
Bar graph
4)NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5)TEMP T1, T2, TD

This multi-parameter Patient Monitor also have the following functions:
-audible and visual alarm,
-trend data storage and output,
-NIBP measurement,
-alarm event marking and drug concentration calculation, etc.


Performance
 
ECG Lead mode: 3-lead or 5-lead
Lead selection: I, II, III, aVR, aVL, aVF, V
Waveform: 5-lead, 2-channel
3-lead, 1-channel
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
HR Measurement and alarm range: 15~350bpm
Accuracy: ±1% or ±1bpm, whichever is greater
Alarm accuracy: ± 2 bpm
Resolution: 1 bpm
ST-segment monitoring:
Measurement and alarm range: -2.0mV~+2.0mV
Accuracy: -0.8mV~+0.8mV ±0.04mv or ±10%, whichever is greater 
Other range: unspecified 
Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Respiration Method: R-F(RA-LL) Impedance 
Respiration rate: 
Measurement and alarm range: 0~150rpm
Resolution: 1 rpm
Measurement accuracy: ±2 rpm
Alarm accuracy: ±3 rpm
Apnea alarm: 10~40s
Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
NIBP Method: Oscillometry
Mode: Manual/AUTO/STAT 
Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes
Measurement period in STAT mode: 5 minutes
Measurement and alarm range: 10 ~ 270 mmHg
Resolution: 1 mmHg
Cuff pressure accuracy: ±3 mmHg
Measurement accuracy:
Maximal mean deviation: ±5 mmHg
Maximal standard deviation: 8mmHg
Over-pressure protection:
Adult mode: 297±3 mmHg
Pediatric mode: 240±3 mmHg
Neonatal mode: 147±3 mmHg
SpO2 Measurement and alarm range: 0 ~ 100%
Resolution: 1%
Measurement accuracy: 70%~100%: ±2%; 
0%~69%: unspecified 
PR Measurement and alarm range: 30 ~ 250 bpm
Measurement accuracy: ±2 bpm or ±2%, whichever is greater
TEMP Channel: dual-channel
Measurement and alarm range: 0 ~ 50ºC
Resolution: 0.1 ºC
Accuracy: ±0.1 ºC
EtCO2 Method: Sidestream or Mainstream 
Measurement range for CO2: 0 ~ 150mmHg
Resolution for CO2:
0.1 mm Hg: 0 ~ 69 mm Hg
0.25 mm Hg: 70 ~ 150 mm Hg
Accuracy for CO2:
0 ~ 40 mm Hg: ±2 mm Hg
41 ~ 70 mm Hg: ±5%
71 ~ 100 mm Hg: ±8%
101 ~ 150 mm Hg: ±10%
AwRR range: 2~150 rpm
AwRR accuracy: ±1 rpm
Apnea alarm: yes
IBP
 
Channel: dual-channel
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measurement and alarm range: -10~300 mm Hg
Resolution: 1 mmHg
Accuracy: ±2% or 1mm Hg, whichever is greater
Power supply:100-240V~, 50/60Hz
Safety classification: Class I, type CF defibrillation-proof applied part

Accessories
Adult fingertip SpO2 probe (5-pin)
Adult NIBP cuff 
NIBP extension tube
ECG lead cable
ECG electrode
Temperature probe
Power adapter
Power cord 
User Manual 


Optional:
Etco2,IBP,Printer,Trolley


Physical characteristic
Dimension: 235 mm(L) × 141 mm(W) × 222 mm(H)
Weight: 2.5 Kg


Certificate
CE


CONTEC MEDICAL SYSTEMS CO., LTD

Product List:
-TELEMEDICINE products
-Pulse oximeter
-Patient Monitoring
-ECG machine(Electrocardiograph)/Holter ECG/Stress test ECG,
-EEG,
-Ultrasound Imaging,Pocket fetal doppler,fetal monitor,
-Blood pressure Monitor(ABPM),
-spirometer
-infusion/syringe Pump
-Digital Stethscope
-In-Vitro Diagnostics
-simulator
-Veterinary products


Real Manufacturer Contec Cms6000 FDA Ce Medical Examiner Equipment Patient Monitor Vital Sign Real manufacturer CONTEC CMS6000 FDA CE medical examiner equipment patient monitor vital sign
Model:CMS6000    Brand:CONTEC

Real Manufacturer Contec Cms6000 FDA Ce Medical Examiner Equipment Patient Monitor Vital Sign

CMS6000
 CE approved Portable Multiparameter Patient Monitor with 8'' TFT color LCD:
1All-round monitor for adult, pediatric and neonate.
2.Multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakhstan, Polish, Czech).
3.
Connect to Central Monitoring System by 3G, WiFi or wired mode.
4.Achieve data storage and software updating by USB interface
 
Main Features

1.Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
2.With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.
3.Waveform, parameter color and location can be set optionally.
4.Operation mode: keys and buttons.
5.Display up to 8-channel waveform on one screen.
6.Display 7-lead ECG waveform on one screen, and with ECG step function.
7.Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
8.HRV analysis function.
9.NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
10.Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
11.Drug concentration calculation and titration table functions.
12.Print trend table data with one-key.
13.AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
14.Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary).

Functions
Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
1)ECG Heart rate(HR)
ECG waveform 
Arrhythmia and ST-segment analysis
2)RESP Respiration rate(RR)
Respiration waveform
3)SpO2 Oxygen saturation(SpO2)
Plethysmogram(PLETH) waveform
Pulse rate(PR)
Bar graph
4)NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5)TEMP T1, T2, TD

This multi-parameter Patient Monitor also have the following functions:
-audible and visual alarm,
-trend data storage and output,
-NIBP measurement,
-alarm event marking and drug concentration calculation, etc.


Performance
 
ECG Lead mode: 3-lead or 5-lead
Lead selection: I, II, III, aVR, aVL, aVF, V
Waveform: 5-lead, 2-channel
3-lead, 1-channel
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
HR Measurement and alarm range: 15~350bpm
Accuracy: ±1% or ±1bpm, whichever is greater
Alarm accuracy: ± 2 bpm
Resolution: 1 bpm
ST-segment monitoring:
Measurement and alarm range: -2.0mV~+2.0mV
Accuracy: -0.8mV~+0.8mV ±0.04mv or ±10%, whichever is greater 
Other range: unspecified 
Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Respiration Method: R-F(RA-LL) Impedance 
Respiration rate: 
Measurement and alarm range: 0~150rpm
Resolution: 1 rpm
Measurement accuracy: ±2 rpm
Alarm accuracy: ±3 rpm
Apnea alarm: 10~40s
Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
NIBP Method: Oscillometry
Mode: Manual/AUTO/STAT 
Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes
Measurement period in STAT mode: 5 minutes
Measurement and alarm range: 10 ~ 270 mmHg
Resolution: 1 mmHg
Cuff pressure accuracy: ±3 mmHg
Measurement accuracy:
Maximal mean deviation: ±5 mmHg
Maximal standard deviation: 8mmHg
Over-pressure protection:
Adult mode: 297±3 mmHg
Pediatric mode: 240±3 mmHg
Neonatal mode: 147±3 mmHg
SpO2 Measurement and alarm range: 0 ~ 100%
Resolution: 1%
Measurement accuracy: 70%~100%: ±2%; 
0%~69%: unspecified 
PR Measurement and alarm range: 30 ~ 250 bpm
Measurement accuracy: ±2 bpm or ±2%, whichever is greater
TEMP Channel: dual-channel
Measurement and alarm range: 0 ~ 50ºC
Resolution: 0.1 ºC
Accuracy: ±0.1 ºC
EtCO2 Method: Sidestream or Mainstream 
Measurement range for CO2: 0 ~ 150mmHg
Resolution for CO2:
0.1 mm Hg: 0 ~ 69 mm Hg
0.25 mm Hg: 70 ~ 150 mm Hg
Accuracy for CO2:
0 ~ 40 mm Hg: ±2 mm Hg
41 ~ 70 mm Hg: ±5%
71 ~ 100 mm Hg: ±8%
101 ~ 150 mm Hg: ±10%
AwRR range: 2~150 rpm
AwRR accuracy: ±1 rpm
Apnea alarm: yes
IBP
 
Channel: dual-channel
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measurement and alarm range: -10~300 mm Hg
Resolution: 1 mmHg
Accuracy: ±2% or 1mm Hg, whichever is greater
Power supply:100-240V~, 50/60Hz
Safety classification: Class I, type CF defibrillation-proof applied part

Accessories
Adult fingertip SpO2 probe (5-pin)
Adult NIBP cuff 
NIBP extension tube
ECG lead cable
ECG electrode
Temperature probe
Power adapter
Power cord 
User Manual 


Optional:
Etco2,IBP,Printer,Trolley


Physical characteristic
Dimension: 235 mm(L) × 141 mm(W) × 222 mm(H)
Weight: 2.5 Kg


Certificate
CE


CONTEC MEDICAL SYSTEMS CO., LTD

Product List:
-TELEMEDICINE products
-Pulse oximeter
-Patient Monitoring
-ECG machine(Electrocardiograph)/Holter ECG/Stress test ECG,
-EEG,
-Ultrasound Imaging,Pocket fetal doppler,fetal monitor,
-Blood pressure Monitor(ABPM),
-spirometer
-infusion/syringe Pump
-Digital Stethscope
-In-Vitro Diagnostics
-simulator
-Veterinary products


Real Manufacturer Contec Cms6000 FDA Ce Medical Examiner Equipment Patient Monitor Vital Sign

Fresh onion

Yellow Onions,Fresh Onion,White Onion

Toboli International Trading Co., Ltd. , http://www.jnapplefruit.com