Talk about the cause of the damage of the screw hoist

After the screw hoist has been used for a long time, if it is not regularly inspected and maintained, it is easy to have various problems. If these problems are not solved, the screw hoist will be damaged. Let us analyze the cause of the damage caused by the screw hoist.
1. When the spiral hoist is initially feeding, the feeding speed should be gradually increased until the rated conveying capacity is reached, and the feeding should be uniform, otherwise it will easily cause the accumulation of the conveying materials and the overload of the driving device, so that the whole machine is damaged prematurely.
2. The material to be conveyed shall not be mixed with hard large materials to avoid the screw jam and cause damage to the screw hoist.
3. Any abnormality in the operation of the screw hoist should be checked and eliminated, and it must not be forced to run.
4. Always check the working status of the components of the screw hoist during use. Pay attention to whether the fasteners are loose. If the parts are loose, immediately tighten the screws to retighten them.
5. The screw hoist should start without load, that is, start when there is no material in the shell, and start feeding to the screw hoist after starting.
6. The moving parts of the spiral hoist should be regularly lubricated.
The above is the analysis of the cause of the damage of the screw hoist. If there is a similar problem, you may wish to find the reason according to the above analysis.

Metatron Hunter 4025 NLS

Metatron Hunter 4025:

Description and Field of Application
Purpose
The Metapathia-GR Hunter software can operate only with the telemetric nonlinear analysis data processing apparatus "Metatron" and its subsequent modifications. The telemetric nonlinear analysis data processing device is compatible with the IBM-type PCs and intended for studying reaction of a biological object to different types of the informational impact. "Metatron" allows correlating the measurement process with the process affecting it and performs the following.


Operations:
1) It measures J (0) which mirrors the change of the describing parameter, and the entropic potential relative to its ini- tial value;
2) It transforms continuous signal J (0) with the preset intervals of frequencies into a histogram (a row of numerical val-ues of scanned frequencies with serial numbers from 1.8 to 8.2 Hz.);
3) It sends the current W values to PC and displays the graph on the monitor simultaneously with its impact on the examinee.
4) It accumulates the W value in its memory unit, if observing the histogram is more convenient upon completion of the measurements;
5) It issues the scale-correlated commands required for regulating the effect on the examinee at testing;
6) It transmits the W values from the unit into PC memory upon completion of the measurements and saves them in unit memory of prior to the beginning of recording data of the next measurements.


Telemetric nonlinear analysis data processing apparatus "Metatron" (hereinafter "apparatus") can be used for non-linear analysis of biological structures and testing of biologically active supplements. The apparatus can also be used in research centers and scientific research facilities.

Metatron Hunter 4025

The apparatus is intended to register psychophysics changes in system and allows to:


- Get qualitative estimation of functional condition in a form of topical analysis.
- Control effectiveness and results of different ways of treatment.
- Analyze dynamics of functional condition changes over period of time.
- Determine initial nidus of functional breach.
- Estimate character of changes using expert systems.
- Estimate basic characteristics of bio-system homeostasis.
Metatron Hunter 4025


Metatron Hunter 4025,Metapathia Gr Hunter 4025,Metatron 4025 Nls,Metatron Gr Hunter 4025

Shenzhen Guangyang Zhongkang Technology Co., Ltd. , https://www.syztreatment.com